Cleaning cartridge for AIT-5 drives - Automatically detects head conditions to implement a specific cleaning cycle under an optimum setting. |
| SDX5-CL | |
|---|---|
| Tape Width (mm) | 8 |
| Tape Thickness (µm) | 6.1 |
| Number of Cleaning Times | Average 80 times |
| Usable Drives | AIT-5 drive |
| Environmental Requirements | Operation Conditions (°F(°C);%RH) : 41~113(5~45)/20~80 * Storage Conditions (°F(°C);%RH) : 41~90(5~32)/20~60 * Transportation Conditions (°F(°C);%RH) :-40~113(-40~45)/5~80 * |
* Maximum wet bulb temperature : No condensation at 79°F (26°C).
|
|
Cleaning cartridge for AIT-4 drives - Automatically detects head conditions to implement a specific cleaning cycle under an optimum setting. |
| SDX4-CLL | |
|---|---|
| Tape Width (mm) | 8 |
| Tape Thickness (µm) | 6.1 |
| Number of Cleaning Times | Average 50 times |
| Usable Drives | AIT-4 drive |
| Environmental Requirements | Operation Conditions (°F(°C);%RH) : 41~113(5~45)/20~80 * Storage Conditions (°F(°C);%RH) : 41~90(5~32)/20~60 * Transportation Conditions (°F(°C);%RH) :-40~113(-40~45)/5~80 * |
* Maximum wet bulb temperature : No condensation at 79°F (26°C).
|
|
Cleaning cartridge for IT-3Ex drives - Automatically detects head conditions to implement a specific cleaning cycle under an optimum setting. |
| SDX3X-CL | |
|---|---|
| Tape Width (mm) | 8 |
| Tape Thickness (µm) | 6.1 |
| Number of Cleaning Times | Average 80 times |
| Usable Drives | AIT-3Ex drive |
| Environmental Requirements | Operation Conditions (°F(°C);%RH) : 41~113(5~45)/20~80 * Storage Conditions (°F(°C);%RH) : 41~90(5~32)/20~60 * Transportation Conditions (°F(°C);%RH) :-40~113(-40~45)/5~80 * |
* Maximum wet bulb temperature : No condensation at 79°F (26°C).
|
|
This cleaning cartridge is designed exclusively for AIT-1, AT-2, AIT-3, AIT-E Turbo, AIT-1 Turbo, and AIT-2 Turbo drives. The AIT drives come with a self-cleaning mechanism and thus do not require frequent cleaning. Use this cartridge when the drive's cleaning lamp is lit. |
| SDX1-CL | |
|---|---|
| Tape Width (mm) | 8 |
| Tape Thickness (µm) | 7.5 |
| Number of Cleaning Times | Approx 60 times (AIT-1 drive, AIT-2 dirve, AIT-E Turbo drive, AIT-1 Turbo
drive) Approx 55 times (AIT-2 Turbo drive , AIT-3 drive) |
| Usable Drives | AIT-1, AIT-2, AIT-3, AIT-E Turbo, AIT-1 Turbo, AIT-2 Turbo drives |
| Environmental Requirements | Operation Conditions (°F(°C);%RH) : 41~113(5~45)/20~80 * Storage Conditions (°F(°C);%RH) : 41~90(5~32)/20~60 * Transportation Conditions (°F(°C);%RH) :-40~113(-40~45)/5~80 * |
* Maximum wet bulb temperature : No condensation at 79°F (26°C).
|
|
This cleaning cartridge can be used in all DDS and DAT72 drives. The tape thickness has been reduced and the head wear minimized to make it particularly well-suited for the DDS3, DDS4, and DAT72 drives and enable it to provide the best head-cleaning performance possible. It will provide approximately 50 cleanings (depending on the drive). Sony recommends its use every 25 hours, although the actual cleaning frequency will vary depending on the operating environment. |
| DGD15CL | |
|---|---|
| Tape Width (mm) | 3.8 |
| Tape Thickness (µm) | 7.0 |
| Number of Cleaning Times | Approx. 50 times |
| Usable Drives | All DDS drive, DAT72 drive |
| Environmental Requirements |
Operation Conditions (°F(°C);%RH) : 59~131(15~55)/10~80 * Storage Conditions (°F(°C);%RH) :41~90(5~32)/20~60 * Transportation Conditions (°F(°C);%RH) :-40~113(-40~45)/5~80 * |
* Maximum wet bulb temperature : No condensation at 79°F (26°C).
|
|
The DLT Cleaning cartridge III can be used with all DLT drives. Use this tape as necessary or when the Use Cleaning Tape lamp of the drive is lit. It will provide approximately 20 cleanings. * DLT drives: DLT2000, DLT2000XT, DLT4000, DLT7000, and DLT8000 |
| DL3CL | |
|---|---|
| Tape Width (mm) | 12.65 |
| Tape Thickness (µm) | 8.9 |
| Minimum Tape Length (m) | 365 |
| Number of Cleaning Times | Approx. 20times |
| Usable Drives | DLTdrive |
| Environmental Requirements | Operation Conditions (°F(°C);%RH) : 50~104(10~40)/20~80 * Storage Conditions (°F(°C);%RH) : 60~90(16~32)/20~80 * Transportation Conditions (°F(°C);%RH) :-9~118(-23~48)/5~80 * |
* Maximum wet bulb temperature : No condensation at 79°F (26°C).
|
|
The DLT VS160 cleaning cartridge is designed for use with DLT VS160 drives and DLT-V4 drives. Use this tape as necessary, when the Use Cleaning Tape lamp of the drive is lit, or when a cleaning message appears during the use of backup software. It will provide approximately 20 cleanings. * This tape cannot be used with the DLT IV and DLT VS80 drives. |
|
Note: Packagings of those 2 products above are different from each other, but the cartridges/tapes inside of those packagings are just the same, and both products are available with DLTVS160 drives/ DLT-V4 drives. |
| DLTVS1-CL | |
|---|---|
| Tape Width (mm) | 12.65 |
| Tape Thickness (µm) | 8.9 |
| Number of Cleaning Times | Approx. 20times |
| Usable Drives | DLT VS160 drive / DLT-V4 drive |
| Environmental Requirements | Operation Conditions (°F(°C);%RH) : 50~104(10~40)/20~80 * Storage Conditions (°F(°C);%RH) : 61~90(16~32)/20~80 * Transportation Conditions (°F(°C);%RH) :-9~118(-23~48)/5~80 * |
* Maximum wet bulb temperature : No condensation at 79°F (26°C).
|
|
The SDLT cleaning cartridge is designed for use with SDLT drives. Use this tape as necessary, when the Use Cleaning Tape lamp of the drive is lit, or when a cleaning message appears during the use of backup software. It will provide approximately 20 cleanings. * SDLT drives: SDLT220 and SDLT320 |
| SDLT-CL | |
|---|---|
| Tape Width (mm) | 12.65 |
| Tape Thickness (µm) | 8.9 |
| Number of Cleaning Times | Approx. 20times |
| Usable Drives | SDLTdrive |
| Environmental Requirements | Operation Conditions (°F(°C);%RH) : 50~104(10~40)/20~80 * Storage Conditions (°F(°C);%RH) : 61~90(16~32)/20~80 * Transportation Conditions (°F(°C);%RH) :-9~118(-23~48)/5~80 * |
* Maximum wet bulb temperature : No condensation at 79°F (26°C).
|
|
Ultrium LTO Universal Cleaning Cartridge. |
| LTX-CL | |
|---|---|
| Tape Width (mm) | 12.65 |
| Tape Thickness (µm) | 8.9 |
| Tape Long (m) | 319 |
| Number of Cleaning Times | Approx. 50 times ( drive dependent ) |
| Usable Drives | All Ultrium drive |
| Environmental Requirements |
Operation Conditions (°F(°C);%RH) : 50~113(10~45)/20~80 * Storage Conditions (°F(°C);%RH) : 61~90(16~32)/20~80 * Transportation Conditions (°F(°C);%RH) :-9~120(-23~49)/5~80 * |
* Maximum wet bulb temperature : No condensation at 79°F (26°C).
|
|
| SAIT1-CL | |
|---|---|
| Tape Width (mm) | 12.65 |
| Tape Thickness (µm) | 7.0 |
| Number of Cleaning Times | Approx. 50 times *1 |
| Usable Drives | SAIT-1 drive |
| Environmental Requirements | Operation Conditions :5~45°C/20~80%RH *2 Storage Conditions:16~32°C/20~60%RH *2 Transportation Conditions :-23~48°C/5~80%RH *2 |
*1 The actual number of cleaning cycles depends on the usage conditions.
*2 Maximum wet bulb temperature : No condensation at 79°F (26°C).
|
|
| SAIT2-CL | |
|---|---|
| Tape Width (mm) | 12.65 |
| Tape Thickness (µm) | 7.0 |
| Number of Cleaning Times | Approx. 50 times *1 |
| Usable Drives | SAIT-2 drive |
| Environmental Requirements | Operation Conditions :5~45°C/20~80%RH *2 Storage Conditions:16~32°C/20~60%RH *2 Transportation Conditions :-23~48°C/5~80%RH *2 |
*1 The actual number of cleaning cycles depends on the usage conditions.
*2 Maximum wet bulb temperature : No condensation at 79°F (26°C).
|
|
This cleaning tape is designed for use with D8 drives. It has been approved by Exabyte, the manufacturer that developed the D8. It will provide approximately 18 cleanings. Sony recommends its use every 72 hours or once a month, although the actual cleaning frequency will vary depending on the operating environment. * This tape is designed exclusively for use with D8 drives and cannot be used with the Mammoth or VXA drives. |
| QGD8CL | |
|---|---|
| Tape Width (mm) | 8 |
| Tape Thickness (µm) | 7.8 |
| Number of Cleaning Times | Approx. 18 times |
| Usable Drives | All D8 Drive |
| Environmental Requirements |
Operation Conditions (°F(°C);%RH) :41~113 (5~45)/20~80 * Storage Conditions (°F(°C);%RH) :41~90 (5~32)/20~60 * Transportation Conditions (°F(°C);%RH) :-40~113(-40~45)/5~80 * |
* Maximum wet bulb temperature : No condensation at 79°F (26°C).
|
|
This cleaning cartridge is designed for use with the Mammoth drive. It has been approved by Exabyte, the manufacturer that developed the Mammoth format. It will provide approximately 18 cleanings. Sony recommends its use every 72 hours or once a month, although the actual cleaning frequency will vary depending on the operating environment. * This tape is designed exclusively for use with the Mammoth drive and cannot be used with D8 or VXA drives. |
| QGD-CL1 | |
|---|---|
| Tape Width (mm) | 8 |
| Tape Thickness (µm) | 7.8 |
| Number of Cleaning Times | Approx. 18 times |
| Usable Drives | All Mammoth drive |
| Environmental Requirements |
Operation Conditions (°F(°C);%RH) : 41~113(5~45)/10~88 * Storage Conditions (°F(°C);%RH) :41~90(5~32)/20~60 * Transportation Conditions (°F(°C);%RH) :-40~113(-40~45)/5~80 * |
* Maximum wet bulb temperature : No condensation at 79°F (26°C).
|
|
GW-90CL (S size) |